Ported from sourceful-hugin/device-support/drivers/lua/deye.lua with the v2.1 API idiom — level-string on host.log, _le suffix on decode helpers, host.emit_metric for scalar diagnostics, DRIVER + PROTOCOL table for catalog discovery. Adds hardware-stable identity (host.set_make + SN read from regs 3-7) and battery control (EMS mode 3 + forced power limit on regs 141/143/144) on top of the pure-telemetry hugin source. Every modbus_read is pcall-wrapped so a single register stall can't break the poll, and driver_cleanup / driver_default_mode both revert to self-consumption so the inverter can't get stuck in forced mode if the EMS goes away. HV vs LV battery is auto-detected from register 0 at init; scale factors for PV power, battery voltage, and battery power follow. Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
github-actions Bot
pushed a commit
to erikarenhill/forty-two-watts
that referenced
this pull request
Apr 15, 2026
## 1.0.0 (2026-04-15) ### Bug Fixes * **ci:** switch semantic-release to conventionalcommits preset ([15290c7](15290c7)) * Lua driver Command() reading wrong field — Sungrow ignored targets ([9237156](9237156)) ### Drivers * add Eastron SDM630 Lua driver ([srcfl#18](https://github.com/erikarenhill/forty-two-watts/issues/18)) ([d5ad806](d5ad806)) * add Ferroamp Modbus driver (alt transport to ferroamp.lua) ([srcfl#31](https://github.com/erikarenhill/forty-two-watts/issues/31)) ([03b802c](03b802c)) * port Deye SUN-SG hybrid inverter to 42W v2.1 Lua host ([srcfl#29](https://github.com/erikarenhill/forty-two-watts/issues/29)) ([df8fbc0](df8fbc0)) * port Fronius GEN24 (SunSpec) to Lua ([srcfl#19](https://github.com/erikarenhill/forty-two-watts/issues/19)) ([c1fc875](c1fc875)) * port Fronius Smart Meter (SunSpec Modbus, read-only) ([srcfl#24](https://github.com/erikarenhill/forty-two-watts/issues/24)) ([575895c](575895c)) * port GoodWe hybrid inverter (ET-Plus / EH) to Lua v2.1 ([srcfl#28](https://github.com/erikarenhill/forty-two-watts/issues/28)) ([e43d2d9](e43d2d9)) * port Growatt hybrid inverter driver (read-only) ([srcfl#20](https://github.com/erikarenhill/forty-two-watts/issues/20)) ([92524ac](92524ac)) * port Huawei SUN2000 hybrid inverter ([srcfl#15](https://github.com/erikarenhill/forty-two-watts/issues/15)) ([09a8855](09a8855)) * port Kostal Plenticore / Piko IQ (Lua, read-only) ([srcfl#21](https://github.com/erikarenhill/forty-two-watts/issues/21)) ([bdeca96](bdeca96)) * port Pixii PowerShaper battery driver to v2.1 Lua host ([srcfl#22](https://github.com/erikarenhill/forty-two-watts/issues/22)) ([70a96d1](70a96d1)) * port SMA hybrid inverter Lua driver ([srcfl#23](https://github.com/erikarenhill/forty-two-watts/issues/23)) ([dd34555](dd34555)) * port Sofar HYD-ES/HYD-EP from hugin to Lua v2.1 ([srcfl#26](https://github.com/erikarenhill/forty-two-watts/issues/26)) ([14f6131](14f6131)) * port SolarEdge SunSpec inverter + meter to Lua (read-only) ([srcfl#30](https://github.com/erikarenhill/forty-two-watts/issues/30)) ([1007e63](1007e63)) * port Solis hybrid inverter ([srcfl#27](https://github.com/erikarenhill/forty-two-watts/issues/27)) ([98b2a50](98b2a50)) * port Victron Energy GX Modbus driver ([srcfl#25](https://github.com/erikarenhill/forty-two-watts/issues/25)) ([ad71db2](ad71db2)) ### UI * inline target on hover + driver card + collapsible model cards ([de88f43](de88f43)) * legend wrap + nice-tick y-axis + cleaner chart labels ([srcfl#33](https://github.com/erikarenhill/forty-two-watts/issues/33)) ([aeb1d1c](aeb1d1c)) * live version from API + no-cache headers on static assets ([7b8779b](7b8779b)) ### Control loop * fold live DerEV readings into the EV clamp ([srcfl#36](https://github.com/erikarenhill/forty-two-watts/issues/36)) ([5d57d68](5d57d68)) ### MPC planner * fall back to forecast when learned PV twin collapses ([srcfl#39](https://github.com/erikarenhill/forty-two-watts/issues/39)) ([f3062ac](f3062ac)) ### Telemetry * add DerEV type for EV charger readings ([srcfl#34](https://github.com/erikarenhill/forty-two-watts/issues/34)) ([65c9e2c](65c9e2c)) ### TSDB * long-format SQLite (14d) + Parquet rolloff for older ([c53c964](c53c964)) ### Safety * watchdog marks stale drivers offline + reverts to autonomous ([519196c](519196c))
Contributor
|
🎉 This PR is included in version 2.0.1 🎉 The release is available on GitHub release Your semantic-release bot 📦🚀 |
github-actions Bot
pushed a commit
that referenced
this pull request
Apr 16, 2026
## [0.4.0](v0.3.0...v0.4.0) (2026-04-16) ### Features * config/UI improvements — kWh display, secure EV password, planner tab ([#65](#65)) ([35ab03d](35ab03d)) * Easee Cloud driver + host.http_get/post for Lua drivers ([#56](#56)) ([4cdc942](4cdc942)) * EV charger config + credential masking in API responses ([#58](#58)) ([c22cb80](c22cb80)) ### Bug Fixes * 5 Go-side P1 bugs from Codex review ([#46](#46)) ([0cd2885](0cd2885)) * 5 Go-side P1 bugs from Codex review ([#47](#47)) ([4f2eaf6](4f2eaf6)) * address P2 review comments across control, MPC, drivers, and UI ([#64](#64)) ([fcafa88](fcafa88)) * **ci:** disable @semantic-release/github PR annotation features ([4020d46](4020d46)), closes [#32](#32) [#33](#33) [#34](#34) [#35](#35) [#36](#36) [#39](#39) * **ci:** switch semantic-release to conventionalcommits preset ([7e0bb89](7e0bb89)) * **ci:** upgrade GitHub Actions to Node.js 24 (drop deprecated Node 20) ([4005bd8](4005bd8)) * Lua driver Command() reading wrong field — Sungrow ignored targets ([9237156](9237156)) * populate EV Charger tab from driver config when ev_charger is empty ([5e6b116](5e6b116)) * remove dead evSlider event listeners that crash app.js ([8ae76c7](8ae76c7)) * replace wonky Catmull-Rom spline with simple linear forecast ([abea431](abea431)) * show '...' instead of stale v0.1.0 while JS loads version ([dc65065](dc65065)) * **solaredge_pv:** read SunSpec scale factors every poll, not cached ([#38](#38)) ([26f8793](26f8793)) ### Drivers * add Eastron SDM630 Lua driver ([#18](#18)) ([d5ad806](d5ad806)) * add Ferroamp Modbus driver (alt transport to ferroamp.lua) ([#31](#31)) ([03b802c](03b802c)) * fix 9 P1 bugs flagged by Codex review ([#44](#44)) ([b20e485](b20e485)) * port Deye SUN-SG hybrid inverter to 42W v2.1 Lua host ([#29](#29)) ([df8fbc0](df8fbc0)) * port Fronius GEN24 (SunSpec) to Lua ([#19](#19)) ([c1fc875](c1fc875)) * port Fronius Smart Meter (SunSpec Modbus, read-only) ([#24](#24)) ([575895c](575895c)) * port GoodWe hybrid inverter (ET-Plus / EH) to Lua v2.1 ([#28](#28)) ([e43d2d9](e43d2d9)) * port Growatt hybrid inverter driver (read-only) ([#20](#20)) ([92524ac](92524ac)) * port Huawei SUN2000 hybrid inverter ([#15](#15)) ([09a8855](09a8855)) * port Kostal Plenticore / Piko IQ (Lua, read-only) ([#21](#21)) ([bdeca96](bdeca96)) * port Pixii PowerShaper battery driver to v2.1 Lua host ([#22](#22)) ([70a96d1](70a96d1)) * port SMA hybrid inverter Lua driver ([#23](#23)) ([dd34555](dd34555)) * port Sofar HYD-ES/HYD-EP from hugin to Lua v2.1 ([#26](#26)) ([14f6131](14f6131)) * port SolarEdge SunSpec inverter + meter to Lua (read-only) ([#30](#30)) ([1007e63](1007e63)) * port Solis hybrid inverter ([#27](#27)) ([98b2a50](98b2a50)) * port Victron Energy GX Modbus driver ([#25](#25)) ([ad71db2](ad71db2)) ### UI * add status bar with driver health indicators ([b048d60](b048d60)) * EV status card + Easee control commands ([#59](#59)) ([b03749a](b03749a)) * fix summary cards grid for 7 cards + raise side-by-side breakpoint ([6e19973](6e19973)) * inline target on hover + driver card + collapsible model cards ([de88f43](de88f43)) * legend wrap + nice-tick y-axis + cleaner chart labels ([#33](#33)) ([aeb1d1c](aeb1d1c)) * remove manual EV charging slider ([063174c](063174c)) * show mode band in plan chart + grid target on status card ([877e0bd](877e0bd)) * smooth Catmull-Rom spline for forecast + 15min forecast zone ([dba51a5](dba51a5)) ### Control loop * fold live DerEV readings into the EV clamp ([#36](#36)) ([5d57d68](5d57d68)) * slew-rate anchors on actual battery power, not stale command ([#41](#41)) ([4f73f19](4f73f19)) ### MPC planner * fall back to forecast when learned PV twin collapses ([#39](#39)) ([f3062ac](f3062ac)) * log optimize params + ems_mode per action for plan chart ([9e8c14b](9e8c14b)) * value SoC at import−export spread in self-consumption modes ([#40](#40)) ([a90d525](a90d525)) ### Telemetry * add DerEV type for EV charger readings ([#34](#34)) ([65c9e2c](65c9e2c)) ### TSDB * long-format SQLite (14d) + Parquet rolloff for older ([c53c964](c53c964)) ### Safety * watchdog marks stale drivers offline + reverts to autonomous ([519196c](519196c))
frahlg
added a commit
that referenced
this pull request
Sep 27, 2026
…overs (#1456) * refactor(state,mpc,api): remove dead storage, planner and backup leftovers - #49 Keep on a driver draft now takes the driver update lock and removes the record before the saved original, so an expiry already in flight finishes first and Keep answers 409 instead of "kept" for a reverted draft. - #20 History maintenance runs only the plain SQLite stages. Remove the Parquet archive pipeline (rolloff, aggregate/sample archive, legacy compaction, cold/diagnostic Parquet pruning, Store.Prune) and the unused retentionDays closure of rolloffLoop; keep the Parquet readers. - #40 Drop the hot-history alias (s.hot, hotPath, hotWriteMu), dead hot-only branches and readers, forceRotate, heldBytes, RotateHistory and the test-only historyWriter.maintainHistory. - #41 Remove the always-empty ImportedHistoryFiles filter, the unused coldDir parameter of legacyHistoryIdle and the test-only backup.Restore; round-trip tests now use RestoreContents. - #29 Remove the recourse/multistage challenger, unix and auto transports, transport Health and the stateful shadow evaluator. The worker request keeps the same solver settings as constants; the Energyplan process transport and Core DP shadow are unchanged. - #47 Remove the always-zero PV nameplate and load caps (Service fields, Plan.pv_nameplate_w/load_max_w, forecast ACLimitW/ClampForecasts and their web chart caps), the load rain-check and test-only wrappers. A single sanitiser still maps NaN or negative load to 0 W. - #48 Handshake errors now say the bundled Energyplan worker does not match Core and to run `ftw update` or reinstall. Drop PYTHONPATH and fix stale Update Center, CVXPY, Python shadow and scenario comments. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01MuerPFZFG88kgu8sWVHeq7 * test(mpc): the native contract test no longer expects a scenario model The shared PV scenarios in buildRequest were reachable only by calling ExternalOptimizer directly with a risk margin; production runs through EnergyplanOptimizer, which applies the margin to the slots and zeroes it before the request. Removing that dead block left the native contract test asking for three scenarios. It now checks that a margin never builds a scenario model. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01MuerPFZFG88kgu8sWVHeq7 --------- Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Summary
sourceful-hugin/device-support/drivers/lua/deye.luaintodrivers/deye.luaunder the 42W v2.1 Lua host idiom (DRIVER+PROTOCOLtable, level-string onhost.log,_lesuffix on decode helpers,host.emit_metricfor scalar diagnostics).host.set_make("Deye")+ SN read from holding regs 3-7) and battery control (EMS mode 3 + forced power limit on regs 141 / 143 / 144) on top of the pure-telemetry hugin source.modbus_readispcall-wrapped;driver_cleanupanddriver_default_modeboth revert to self-consumption so the inverter can't get stuck in forced mode if the EMS goes away.Test plan
cd go && go test -count=1 -run TestLua ./internal/drivers/— passcd go && go test -count=1 -run TestCatalog ./internal/drivers/— pass (no tests match, but grep confirmedLoadCatalogpicks up the new entry withid=deye,manufacturer=Deye, protocols + capabilities populated)cd go && go test ./...— full suite green includingdrivers,e2e,control,state🤖 Generated with Claude Code