Skip to content

Drivers: port Fronius Smart Meter (SunSpec Modbus, read-only) - #24

Merged
frahlg merged 1 commit into
masterfrom
worktree-agent-aa24fc83
Apr 15, 2026
Merged

frahlg merged 1 commit into
masterfrom
worktree-agent-aa24fc83

Conversation

@frahlg

@frahlg frahlg commented Apr 15, 2026

Copy link
Copy Markdown
Member

Summary

  • Ports drivers/fronius_smart_meter.lua from sourceful-hugin and rewrites it against the 42W v2.1 Lua host idiom.
  • Three-phase SunSpec meter, all-holding F32 BE register map (currents 40074-40078, voltages 40082-40086, frequency 40096, total + per-phase power 40098-40104, lifetime import/export counters 40138/40130).
  • Complements drivers/fronius.lua (inverter) added by a sibling unit. Flag the meter with is_site_meter: true when it is the household grid-connection meter.

Port notes

  • host.log(msg) → host.log("info", msg)
  • host.decode_u32/i32 → _be variants (this driver reads f32 only)
  • host.decode_f32 → inline IEEE-754 decode (two u16 regs, hi word first); NaN / ±Inf return 0 so SunSpec "not implemented" sentinels do not leak into telemetry.
  • 11 register-read blocks from the hugin original collapsed behind a local read_f32(addr) helper.
  • Fronius Smart Meter already reports import-positive — matches site convention with no sign flip.
  • meter.w, per-phase l{1,2,3}_w/_v/_a, hz, import_wh, export_wh emitted via host.emit("meter", …); phase + frequency diagnostics also land in the long-format TS DB via host.emit_metric.

Tested models

Smart Meter 50kA-3, Smart Meter 63A-3, Smart Meter TS 65A-3.

Test plan

  • go test ./... passes (full Go suite)
  • go test -count=1 ./test/e2e/ passes (full-stack e2e, 25.8 s)
  • gopher-lua smoke test: NewLuaDriver → Init → Poll with a zero-returning Modbus mock runs without error
  • luac -p clean on the file

Generated with Claude Code.

Ports drivers/fronius_smart_meter.lua from sourceful-hugin and rewrites
it against the 42W v2.1 Lua host idiom. Three-phase meter, all-holding
F32 BE SunSpec register map. Complements drivers/fronius.lua (inverter).

Port notes:
- host.log(msg) → host.log("info", msg)
- host.decode_u32/i32 → _be variants (this driver reads f32 only)
- host.decode_f32 → inline IEEE-754 decode (two u16 regs, hi word first);
  treats NaN/Inf as 0 so the SunSpec "not implemented" sentinel doesn't
  leak junk into telemetry
- 11 register reads collapsed behind a local read_f32(addr) helper
- Fronius Smart Meter is already import-positive; matches site
  convention with no sign flip

Tested models: Smart Meter 50kA-3, 63A-3, TS 65A-3.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
@frahlg
frahlg merged commit 575895c into master Apr 15, 2026
github-actions Bot pushed a commit to erikarenhill/forty-two-watts that referenced this pull request Apr 15, 2026
## 1.0.0 (2026-04-15)

### Bug Fixes

* **ci:** switch semantic-release to conventionalcommits preset ([15290c7](15290c7))
* Lua driver Command() reading wrong field — Sungrow ignored targets ([9237156](9237156))

### Drivers

* add Eastron SDM630 Lua driver ([srcfl#18](https://github.com/erikarenhill/forty-two-watts/issues/18)) ([d5ad806](d5ad806))
* add Ferroamp Modbus driver (alt transport to ferroamp.lua) ([srcfl#31](https://github.com/erikarenhill/forty-two-watts/issues/31)) ([03b802c](03b802c))
* port Deye SUN-SG hybrid inverter to 42W v2.1 Lua host ([srcfl#29](https://github.com/erikarenhill/forty-two-watts/issues/29)) ([df8fbc0](df8fbc0))
* port Fronius GEN24 (SunSpec) to Lua ([srcfl#19](https://github.com/erikarenhill/forty-two-watts/issues/19)) ([c1fc875](c1fc875))
* port Fronius Smart Meter (SunSpec Modbus, read-only) ([srcfl#24](https://github.com/erikarenhill/forty-two-watts/issues/24)) ([575895c](575895c))
* port GoodWe hybrid inverter (ET-Plus / EH) to Lua v2.1 ([srcfl#28](https://github.com/erikarenhill/forty-two-watts/issues/28)) ([e43d2d9](e43d2d9))
* port Growatt hybrid inverter driver (read-only) ([srcfl#20](https://github.com/erikarenhill/forty-two-watts/issues/20)) ([92524ac](92524ac))
* port Huawei SUN2000 hybrid inverter ([srcfl#15](https://github.com/erikarenhill/forty-two-watts/issues/15)) ([09a8855](09a8855))
* port Kostal Plenticore / Piko IQ (Lua, read-only) ([srcfl#21](https://github.com/erikarenhill/forty-two-watts/issues/21)) ([bdeca96](bdeca96))
* port Pixii PowerShaper battery driver to v2.1 Lua host ([srcfl#22](https://github.com/erikarenhill/forty-two-watts/issues/22)) ([70a96d1](70a96d1))
* port SMA hybrid inverter Lua driver ([srcfl#23](https://github.com/erikarenhill/forty-two-watts/issues/23)) ([dd34555](dd34555))
* port Sofar HYD-ES/HYD-EP from hugin to Lua v2.1 ([srcfl#26](https://github.com/erikarenhill/forty-two-watts/issues/26)) ([14f6131](14f6131))
* port SolarEdge SunSpec inverter + meter to Lua (read-only) ([srcfl#30](https://github.com/erikarenhill/forty-two-watts/issues/30)) ([1007e63](1007e63))
* port Solis hybrid inverter ([srcfl#27](https://github.com/erikarenhill/forty-two-watts/issues/27)) ([98b2a50](98b2a50))
* port Victron Energy GX Modbus driver ([srcfl#25](https://github.com/erikarenhill/forty-two-watts/issues/25)) ([ad71db2](ad71db2))

### UI

* inline target on hover + driver card + collapsible model cards ([de88f43](de88f43))
* legend wrap + nice-tick y-axis + cleaner chart labels ([srcfl#33](https://github.com/erikarenhill/forty-two-watts/issues/33)) ([aeb1d1c](aeb1d1c))
* live version from API + no-cache headers on static assets ([7b8779b](7b8779b))

### Control loop

* fold live DerEV readings into the EV clamp ([srcfl#36](https://github.com/erikarenhill/forty-two-watts/issues/36)) ([5d57d68](5d57d68))

### MPC planner

* fall back to forecast when learned PV twin collapses ([srcfl#39](https://github.com/erikarenhill/forty-two-watts/issues/39)) ([f3062ac](f3062ac))

### Telemetry

* add DerEV type for EV charger readings ([srcfl#34](https://github.com/erikarenhill/forty-two-watts/issues/34)) ([65c9e2c](65c9e2c))

### TSDB

* long-format SQLite (14d) + Parquet rolloff for older ([c53c964](c53c964))

### Safety

* watchdog marks stale drivers offline + reverts to autonomous ([519196c](519196c))
@github-actions

Copy link
Copy Markdown
Contributor

🎉 This PR is included in version 2.0.1 🎉

The release is available on GitHub release

Your semantic-release bot 📦🚀

github-actions Bot pushed a commit that referenced this pull request Apr 16, 2026
## [0.4.0](v0.3.0...v0.4.0) (2026-04-16)

### Features

* config/UI improvements — kWh display, secure EV password, planner tab ([#65](#65)) ([35ab03d](35ab03d))
* Easee Cloud driver + host.http_get/post for Lua drivers ([#56](#56)) ([4cdc942](4cdc942))
* EV charger config + credential masking in API responses ([#58](#58)) ([c22cb80](c22cb80))

### Bug Fixes

* 5 Go-side P1 bugs from Codex review ([#46](#46)) ([0cd2885](0cd2885))
* 5 Go-side P1 bugs from Codex review ([#47](#47)) ([4f2eaf6](4f2eaf6))
* address P2 review comments across control, MPC, drivers, and UI ([#64](#64)) ([fcafa88](fcafa88))
* **ci:** disable @semantic-release/github PR annotation features ([4020d46](4020d46)), closes [#32](#32) [#33](#33) [#34](#34) [#35](#35) [#36](#36) [#39](#39)
* **ci:** switch semantic-release to conventionalcommits preset ([7e0bb89](7e0bb89))
* **ci:** upgrade GitHub Actions to Node.js 24 (drop deprecated Node 20) ([4005bd8](4005bd8))
* Lua driver Command() reading wrong field — Sungrow ignored targets ([9237156](9237156))
* populate EV Charger tab from driver config when ev_charger is empty ([5e6b116](5e6b116))
* remove dead evSlider event listeners that crash app.js ([8ae76c7](8ae76c7))
* replace wonky Catmull-Rom spline with simple linear forecast ([abea431](abea431))
* show '...' instead of stale v0.1.0 while JS loads version ([dc65065](dc65065))
* **solaredge_pv:** read SunSpec scale factors every poll, not cached ([#38](#38)) ([26f8793](26f8793))

### Drivers

* add Eastron SDM630 Lua driver ([#18](#18)) ([d5ad806](d5ad806))
* add Ferroamp Modbus driver (alt transport to ferroamp.lua) ([#31](#31)) ([03b802c](03b802c))
* fix 9 P1 bugs flagged by Codex review ([#44](#44)) ([b20e485](b20e485))
* port Deye SUN-SG hybrid inverter to 42W v2.1 Lua host ([#29](#29)) ([df8fbc0](df8fbc0))
* port Fronius GEN24 (SunSpec) to Lua ([#19](#19)) ([c1fc875](c1fc875))
* port Fronius Smart Meter (SunSpec Modbus, read-only) ([#24](#24)) ([575895c](575895c))
* port GoodWe hybrid inverter (ET-Plus / EH) to Lua v2.1 ([#28](#28)) ([e43d2d9](e43d2d9))
* port Growatt hybrid inverter driver (read-only) ([#20](#20)) ([92524ac](92524ac))
* port Huawei SUN2000 hybrid inverter ([#15](#15)) ([09a8855](09a8855))
* port Kostal Plenticore / Piko IQ (Lua, read-only) ([#21](#21)) ([bdeca96](bdeca96))
* port Pixii PowerShaper battery driver to v2.1 Lua host ([#22](#22)) ([70a96d1](70a96d1))
* port SMA hybrid inverter Lua driver ([#23](#23)) ([dd34555](dd34555))
* port Sofar HYD-ES/HYD-EP from hugin to Lua v2.1 ([#26](#26)) ([14f6131](14f6131))
* port SolarEdge SunSpec inverter + meter to Lua (read-only) ([#30](#30)) ([1007e63](1007e63))
* port Solis hybrid inverter ([#27](#27)) ([98b2a50](98b2a50))
* port Victron Energy GX Modbus driver ([#25](#25)) ([ad71db2](ad71db2))

### UI

* add status bar with driver health indicators ([b048d60](b048d60))
* EV status card + Easee control commands ([#59](#59)) ([b03749a](b03749a))
* fix summary cards grid for 7 cards + raise side-by-side breakpoint ([6e19973](6e19973))
* inline target on hover + driver card + collapsible model cards ([de88f43](de88f43))
* legend wrap + nice-tick y-axis + cleaner chart labels ([#33](#33)) ([aeb1d1c](aeb1d1c))
* remove manual EV charging slider ([063174c](063174c))
* show mode band in plan chart + grid target on status card ([877e0bd](877e0bd))
* smooth Catmull-Rom spline for forecast + 15min forecast zone ([dba51a5](dba51a5))

### Control loop

* fold live DerEV readings into the EV clamp ([#36](#36)) ([5d57d68](5d57d68))
* slew-rate anchors on actual battery power, not stale command ([#41](#41)) ([4f73f19](4f73f19))

### MPC planner

* fall back to forecast when learned PV twin collapses ([#39](#39)) ([f3062ac](f3062ac))
* log optimize params + ems_mode per action for plan chart ([9e8c14b](9e8c14b))
* value SoC at import−export spread in self-consumption modes ([#40](#40)) ([a90d525](a90d525))

### Telemetry

* add DerEV type for EV charger readings ([#34](#34)) ([65c9e2c](65c9e2c))

### TSDB

* long-format SQLite (14d) + Parquet rolloff for older ([c53c964](c53c964))

### Safety

* watchdog marks stale drivers offline + reverts to autonomous ([519196c](519196c))
@frahlg
frahlg deleted the worktree-agent-aa24fc83 branch August 7, 2026 08:19
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant