Skip to content

UI: EV status card + Easee Phase 2 control - #59

Merged
frahlg merged 1 commit into
masterfrom
worktree-agent-a97969a0
Apr 16, 2026
Merged

frahlg merged 1 commit into
masterfrom
worktree-agent-a97969a0

Conversation

@frahlg

@frahlg frahlg commented Apr 16, 2026

Copy link
Copy Markdown
Member

EV dashboard card + driver_command for start/pause/resume/set_current. go test ./... green.

Dashboard: new EV summary card showing charging power + status
(idle/connected/charging) with color coding. Reads ev_charging_w
from /api/status.

Driver: easee_cloud.lua now implements driver_command for:
- ev_start / ev_pause / ev_resume (charger commands)
- ev_set_current (dynamic current limit, W→A conversion)

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
@frahlg
frahlg merged commit b03749a into master Apr 16, 2026
@github-actions

Copy link
Copy Markdown
Contributor

🎉 This PR is included in version 2.2.0 🎉

The release is available on GitHub release

Your semantic-release bot 📦🚀

@chatgpt-codex-connector chatgpt-codex-connector Bot left a comment

Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

💡 Codex Review

Here are some automated review suggestions for this pull request.

Reviewed commit: fdd640c8be

ℹ️ About Codex in GitHub

Your team has set up Codex to review pull requests in this repo. Reviews are triggered when you

  • Open a pull request for review
  • Mark a draft as ready
  • Comment "@codex review".

If Codex has suggestions, it will comment; otherwise it will react with 👍.

Codex can also answer questions or update the PR. Try commenting "@codex address that feedback".

Comment thread drivers/easee_cloud.lua
elseif action == "ev_resume" then
return post_command("/commands/resume_charging")
elseif action == "ev_set_current" then
local amps = math.floor((power_w or 0) / 230)

Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

P1 Badge Convert EV power to per-phase current before Easee setpoint

ev_set_current derives dynamicChargerCurrent as power_w / 230, but in this repo power_w is a total EV load in watts (the UI range is 0–22000 W, i.e. ~32 A × 230 V × 3). For 3-phase chargers this overstates current by about 3× (e.g. 11 kW becomes 47 A), so the command can be rejected or apply the wrong limit and fail to follow requested charging power. Convert using phase-aware math (and clamp to valid charger current bounds) before posting settings.

Useful? React with 👍 / 👎.

github-actions Bot pushed a commit that referenced this pull request Apr 16, 2026
## [0.4.0](v0.3.0...v0.4.0) (2026-04-16)

### Features

* config/UI improvements — kWh display, secure EV password, planner tab ([#65](#65)) ([35ab03d](35ab03d))
* Easee Cloud driver + host.http_get/post for Lua drivers ([#56](#56)) ([4cdc942](4cdc942))
* EV charger config + credential masking in API responses ([#58](#58)) ([c22cb80](c22cb80))

### Bug Fixes

* 5 Go-side P1 bugs from Codex review ([#46](#46)) ([0cd2885](0cd2885))
* 5 Go-side P1 bugs from Codex review ([#47](#47)) ([4f2eaf6](4f2eaf6))
* address P2 review comments across control, MPC, drivers, and UI ([#64](#64)) ([fcafa88](fcafa88))
* **ci:** disable @semantic-release/github PR annotation features ([4020d46](4020d46)), closes [#32](#32) [#33](#33) [#34](#34) [#35](#35) [#36](#36) [#39](#39)
* **ci:** switch semantic-release to conventionalcommits preset ([7e0bb89](7e0bb89))
* **ci:** upgrade GitHub Actions to Node.js 24 (drop deprecated Node 20) ([4005bd8](4005bd8))
* Lua driver Command() reading wrong field — Sungrow ignored targets ([9237156](9237156))
* populate EV Charger tab from driver config when ev_charger is empty ([5e6b116](5e6b116))
* remove dead evSlider event listeners that crash app.js ([8ae76c7](8ae76c7))
* replace wonky Catmull-Rom spline with simple linear forecast ([abea431](abea431))
* show '...' instead of stale v0.1.0 while JS loads version ([dc65065](dc65065))
* **solaredge_pv:** read SunSpec scale factors every poll, not cached ([#38](#38)) ([26f8793](26f8793))

### Drivers

* add Eastron SDM630 Lua driver ([#18](#18)) ([d5ad806](d5ad806))
* add Ferroamp Modbus driver (alt transport to ferroamp.lua) ([#31](#31)) ([03b802c](03b802c))
* fix 9 P1 bugs flagged by Codex review ([#44](#44)) ([b20e485](b20e485))
* port Deye SUN-SG hybrid inverter to 42W v2.1 Lua host ([#29](#29)) ([df8fbc0](df8fbc0))
* port Fronius GEN24 (SunSpec) to Lua ([#19](#19)) ([c1fc875](c1fc875))
* port Fronius Smart Meter (SunSpec Modbus, read-only) ([#24](#24)) ([575895c](575895c))
* port GoodWe hybrid inverter (ET-Plus / EH) to Lua v2.1 ([#28](#28)) ([e43d2d9](e43d2d9))
* port Growatt hybrid inverter driver (read-only) ([#20](#20)) ([92524ac](92524ac))
* port Huawei SUN2000 hybrid inverter ([#15](#15)) ([09a8855](09a8855))
* port Kostal Plenticore / Piko IQ (Lua, read-only) ([#21](#21)) ([bdeca96](bdeca96))
* port Pixii PowerShaper battery driver to v2.1 Lua host ([#22](#22)) ([70a96d1](70a96d1))
* port SMA hybrid inverter Lua driver ([#23](#23)) ([dd34555](dd34555))
* port Sofar HYD-ES/HYD-EP from hugin to Lua v2.1 ([#26](#26)) ([14f6131](14f6131))
* port SolarEdge SunSpec inverter + meter to Lua (read-only) ([#30](#30)) ([1007e63](1007e63))
* port Solis hybrid inverter ([#27](#27)) ([98b2a50](98b2a50))
* port Victron Energy GX Modbus driver ([#25](#25)) ([ad71db2](ad71db2))

### UI

* add status bar with driver health indicators ([b048d60](b048d60))
* EV status card + Easee control commands ([#59](#59)) ([b03749a](b03749a))
* fix summary cards grid for 7 cards + raise side-by-side breakpoint ([6e19973](6e19973))
* inline target on hover + driver card + collapsible model cards ([de88f43](de88f43))
* legend wrap + nice-tick y-axis + cleaner chart labels ([#33](#33)) ([aeb1d1c](aeb1d1c))
* remove manual EV charging slider ([063174c](063174c))
* show mode band in plan chart + grid target on status card ([877e0bd](877e0bd))
* smooth Catmull-Rom spline for forecast + 15min forecast zone ([dba51a5](dba51a5))

### Control loop

* fold live DerEV readings into the EV clamp ([#36](#36)) ([5d57d68](5d57d68))
* slew-rate anchors on actual battery power, not stale command ([#41](#41)) ([4f73f19](4f73f19))

### MPC planner

* fall back to forecast when learned PV twin collapses ([#39](#39)) ([f3062ac](f3062ac))
* log optimize params + ems_mode per action for plan chart ([9e8c14b](9e8c14b))
* value SoC at import−export spread in self-consumption modes ([#40](#40)) ([a90d525](a90d525))

### Telemetry

* add DerEV type for EV charger readings ([#34](#34)) ([65c9e2c](65c9e2c))

### TSDB

* long-format SQLite (14d) + Parquet rolloff for older ([c53c964](c53c964))

### Safety

* watchdog marks stale drivers offline + reverts to autonomous ([519196c](519196c))
@frahlg
frahlg deleted the worktree-agent-a97969a0 branch August 7, 2026 08:19