Repository navigation
Drivers: port Fronius GEN24 (SunSpec) to Lua - #19
Conversation
Port of sourceful-hugin's fronius.lua to the forty-two-watts v2.1 Lua host idiom. Read-only driver for Fronius Symo/Primo GEN24 hybrid inverters over Modbus TCP (SunSpec). The hugin driver leaned on host.decode_f32 and host.scale, which 42W's host does not expose. Both are now inlined: IEEE 754 single-precision decoding via bit-math on the two u16 registers (big-endian word order), and SunSpec int16 scale factors applied with 10^sf / 10^-sf. Also swaps host.log(msg) for host.log(level, msg) and host.decode_u32/i32 for the _be variants — matches the v2.1 API. Emits pv (with MPPT + lifetime + temp + rated_w), battery (w/v/soc derived from charge/discharge-rate percents × max charge power), and a meter-shaped emission derived from AC values so per-phase data shows up in the TSDB. Sign flip at the boundary: dc_w → -dc_w for PV; discharge_rate drives bat_w negative, charge_rate drives it positive. Scalar diagnostics (MPPT V/A, heatsink temp, grid Hz, per-phase V/A/W, battery DC V) land in the long-format TSDB via emit_metric. Device identity anchors on Fronius SunSpec Common block serial number (holding register 40052, 16 regs / 32 chars); falls back to mac/endpoint when the gateway doesn't expose the common block. Control is intentionally a stub — Fronius GEN24 battery control needs the Modbus-control licence and is out of scope here. Verified: make e2e + go test ./internal/drivers/ + catalog entry parses (id=fronius, name="Fronius GEN24", protocols=[modbus], capabilities=[meter,pv,battery]). Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
There was a problem hiding this comment.
💡 Codex Review
Here are some automated review suggestions for this pull request.
Reviewed commit: ac4ceb002a
ℹ️ About Codex in GitHub
Your team has set up Codex to review pull requests in this repo. Reviews are triggered when you
- Open a pull request for review
- Mark a draft as ready
- Comment "@codex review".
If Codex has suggestions, it will comment; otherwise it will react with 👍.
Codex can also answer questions or update the PR. Try commenting "@codex address that feedback".
| local l3_w = l3_v * l3_a | ||
|
|
||
| host.emit("meter", { | ||
| w = ac_w, |
There was a problem hiding this comment.
Do not publish inverter output as site meter power
meter.w is currently set to ac_w, which is inverter AC output rather than net grid import/export, even though the comment says this block is not a grid-side meter. The control path reads the configured is_site_meter value as the grid feedback signal (go/internal/control/dispatch.go), and config validation requires at least one site meter, so Fronius-only (or misassigned) setups will run dispatch against the wrong signal and command batteries in the wrong direction.
Useful? React with 👍 / 👎.
## 1.0.0 (2026-04-15) ### Bug Fixes * **ci:** switch semantic-release to conventionalcommits preset ([15290c7](15290c7)) * Lua driver Command() reading wrong field — Sungrow ignored targets ([9237156](9237156)) ### Drivers * add Eastron SDM630 Lua driver ([srcfl#18](https://github.com/erikarenhill/forty-two-watts/issues/18)) ([d5ad806](d5ad806)) * add Ferroamp Modbus driver (alt transport to ferroamp.lua) ([srcfl#31](https://github.com/erikarenhill/forty-two-watts/issues/31)) ([03b802c](03b802c)) * port Deye SUN-SG hybrid inverter to 42W v2.1 Lua host ([srcfl#29](https://github.com/erikarenhill/forty-two-watts/issues/29)) ([df8fbc0](df8fbc0)) * port Fronius GEN24 (SunSpec) to Lua ([srcfl#19](https://github.com/erikarenhill/forty-two-watts/issues/19)) ([c1fc875](c1fc875)) * port Fronius Smart Meter (SunSpec Modbus, read-only) ([srcfl#24](https://github.com/erikarenhill/forty-two-watts/issues/24)) ([575895c](575895c)) * port GoodWe hybrid inverter (ET-Plus / EH) to Lua v2.1 ([srcfl#28](https://github.com/erikarenhill/forty-two-watts/issues/28)) ([e43d2d9](e43d2d9)) * port Growatt hybrid inverter driver (read-only) ([srcfl#20](https://github.com/erikarenhill/forty-two-watts/issues/20)) ([92524ac](92524ac)) * port Huawei SUN2000 hybrid inverter ([srcfl#15](https://github.com/erikarenhill/forty-two-watts/issues/15)) ([09a8855](09a8855)) * port Kostal Plenticore / Piko IQ (Lua, read-only) ([srcfl#21](https://github.com/erikarenhill/forty-two-watts/issues/21)) ([bdeca96](bdeca96)) * port Pixii PowerShaper battery driver to v2.1 Lua host ([srcfl#22](https://github.com/erikarenhill/forty-two-watts/issues/22)) ([70a96d1](70a96d1)) * port SMA hybrid inverter Lua driver ([srcfl#23](https://github.com/erikarenhill/forty-two-watts/issues/23)) ([dd34555](dd34555)) * port Sofar HYD-ES/HYD-EP from hugin to Lua v2.1 ([srcfl#26](https://github.com/erikarenhill/forty-two-watts/issues/26)) ([14f6131](14f6131)) * port SolarEdge SunSpec inverter + meter to Lua (read-only) ([srcfl#30](https://github.com/erikarenhill/forty-two-watts/issues/30)) ([1007e63](1007e63)) * port Solis hybrid inverter ([srcfl#27](https://github.com/erikarenhill/forty-two-watts/issues/27)) ([98b2a50](98b2a50)) * port Victron Energy GX Modbus driver ([srcfl#25](https://github.com/erikarenhill/forty-two-watts/issues/25)) ([ad71db2](ad71db2)) ### UI * inline target on hover + driver card + collapsible model cards ([de88f43](de88f43)) * legend wrap + nice-tick y-axis + cleaner chart labels ([srcfl#33](https://github.com/erikarenhill/forty-two-watts/issues/33)) ([aeb1d1c](aeb1d1c)) * live version from API + no-cache headers on static assets ([7b8779b](7b8779b)) ### Control loop * fold live DerEV readings into the EV clamp ([srcfl#36](https://github.com/erikarenhill/forty-two-watts/issues/36)) ([5d57d68](5d57d68)) ### MPC planner * fall back to forecast when learned PV twin collapses ([srcfl#39](https://github.com/erikarenhill/forty-two-watts/issues/39)) ([f3062ac](f3062ac)) ### Telemetry * add DerEV type for EV charger readings ([srcfl#34](https://github.com/erikarenhill/forty-two-watts/issues/34)) ([65c9e2c](65c9e2c)) ### TSDB * long-format SQLite (14d) + Parquet rolloff for older ([c53c964](c53c964)) ### Safety * watchdog marks stale drivers offline + reverts to autonomous ([519196c](519196c))
|
🎉 This PR is included in version 2.0.1 🎉 The release is available on GitHub release Your semantic-release bot 📦🚀 |
## [0.4.0](v0.3.0...v0.4.0) (2026-04-16) ### Features * config/UI improvements — kWh display, secure EV password, planner tab ([#65](#65)) ([35ab03d](35ab03d)) * Easee Cloud driver + host.http_get/post for Lua drivers ([#56](#56)) ([4cdc942](4cdc942)) * EV charger config + credential masking in API responses ([#58](#58)) ([c22cb80](c22cb80)) ### Bug Fixes * 5 Go-side P1 bugs from Codex review ([#46](#46)) ([0cd2885](0cd2885)) * 5 Go-side P1 bugs from Codex review ([#47](#47)) ([4f2eaf6](4f2eaf6)) * address P2 review comments across control, MPC, drivers, and UI ([#64](#64)) ([fcafa88](fcafa88)) * **ci:** disable @semantic-release/github PR annotation features ([4020d46](4020d46)), closes [#32](#32) [#33](#33) [#34](#34) [#35](#35) [#36](#36) [#39](#39) * **ci:** switch semantic-release to conventionalcommits preset ([7e0bb89](7e0bb89)) * **ci:** upgrade GitHub Actions to Node.js 24 (drop deprecated Node 20) ([4005bd8](4005bd8)) * Lua driver Command() reading wrong field — Sungrow ignored targets ([9237156](9237156)) * populate EV Charger tab from driver config when ev_charger is empty ([5e6b116](5e6b116)) * remove dead evSlider event listeners that crash app.js ([8ae76c7](8ae76c7)) * replace wonky Catmull-Rom spline with simple linear forecast ([abea431](abea431)) * show '...' instead of stale v0.1.0 while JS loads version ([dc65065](dc65065)) * **solaredge_pv:** read SunSpec scale factors every poll, not cached ([#38](#38)) ([26f8793](26f8793)) ### Drivers * add Eastron SDM630 Lua driver ([#18](#18)) ([d5ad806](d5ad806)) * add Ferroamp Modbus driver (alt transport to ferroamp.lua) ([#31](#31)) ([03b802c](03b802c)) * fix 9 P1 bugs flagged by Codex review ([#44](#44)) ([b20e485](b20e485)) * port Deye SUN-SG hybrid inverter to 42W v2.1 Lua host ([#29](#29)) ([df8fbc0](df8fbc0)) * port Fronius GEN24 (SunSpec) to Lua ([#19](#19)) ([c1fc875](c1fc875)) * port Fronius Smart Meter (SunSpec Modbus, read-only) ([#24](#24)) ([575895c](575895c)) * port GoodWe hybrid inverter (ET-Plus / EH) to Lua v2.1 ([#28](#28)) ([e43d2d9](e43d2d9)) * port Growatt hybrid inverter driver (read-only) ([#20](#20)) ([92524ac](92524ac)) * port Huawei SUN2000 hybrid inverter ([#15](#15)) ([09a8855](09a8855)) * port Kostal Plenticore / Piko IQ (Lua, read-only) ([#21](#21)) ([bdeca96](bdeca96)) * port Pixii PowerShaper battery driver to v2.1 Lua host ([#22](#22)) ([70a96d1](70a96d1)) * port SMA hybrid inverter Lua driver ([#23](#23)) ([dd34555](dd34555)) * port Sofar HYD-ES/HYD-EP from hugin to Lua v2.1 ([#26](#26)) ([14f6131](14f6131)) * port SolarEdge SunSpec inverter + meter to Lua (read-only) ([#30](#30)) ([1007e63](1007e63)) * port Solis hybrid inverter ([#27](#27)) ([98b2a50](98b2a50)) * port Victron Energy GX Modbus driver ([#25](#25)) ([ad71db2](ad71db2)) ### UI * add status bar with driver health indicators ([b048d60](b048d60)) * EV status card + Easee control commands ([#59](#59)) ([b03749a](b03749a)) * fix summary cards grid for 7 cards + raise side-by-side breakpoint ([6e19973](6e19973)) * inline target on hover + driver card + collapsible model cards ([de88f43](de88f43)) * legend wrap + nice-tick y-axis + cleaner chart labels ([#33](#33)) ([aeb1d1c](aeb1d1c)) * remove manual EV charging slider ([063174c](063174c)) * show mode band in plan chart + grid target on status card ([877e0bd](877e0bd)) * smooth Catmull-Rom spline for forecast + 15min forecast zone ([dba51a5](dba51a5)) ### Control loop * fold live DerEV readings into the EV clamp ([#36](#36)) ([5d57d68](5d57d68)) * slew-rate anchors on actual battery power, not stale command ([#41](#41)) ([4f73f19](4f73f19)) ### MPC planner * fall back to forecast when learned PV twin collapses ([#39](#39)) ([f3062ac](f3062ac)) * log optimize params + ems_mode per action for plan chart ([9e8c14b](9e8c14b)) * value SoC at import−export spread in self-consumption modes ([#40](#40)) ([a90d525](a90d525)) ### Telemetry * add DerEV type for EV charger readings ([#34](#34)) ([65c9e2c](65c9e2c)) ### TSDB * long-format SQLite (14d) + Parquet rolloff for older ([c53c964](c53c964)) ### Safety * watchdog marks stale drivers offline + reverts to autonomous ([519196c](519196c))
Summary
sourceful-hugin/device-support/drivers/lua/fronius.luato 42W's v2.1 Lua host idiom asdrivers/fronius.lua.Port notes
The hugin driver leaned on
host.decode_f32andhost.scale, which 42W's Lua host does not expose. Both are inlined:decode_f32_be(hi, lo)— IEEE 754 single-precision via bit-math on the two u16 registers (big-endian word order). Treats NaN/Inf (SunSpec0x7FC00000) as 0.apply_sf(v, sf)— SunSpec int16 scale factor:v * 10^sf(split on sign).Other API drift fixed:
host.log(msg)→host.log("info", msg);host.decode_u32/i32→_bevariants.Device identity anchors on SunSpec Common block serial number (holding 40052, 16 regs / 32 chars). Falls back to MAC/endpoint when the gateway doesn't expose the common block.
Battery/MPPT control was never implemented in hugin's fronius.lua either — GEN24 Modbus control needs the paid Modbus-control licence; left as a logged stub.
Test plan
go test ./internal/drivers/passesgo test ./...passes (full suite)make e2epassesLoadCatalogpicks up the metadata:id=fronius,name="Fronius GEN24",protocols=[modbus],capabilities=[meter,pv,battery]Co-Authored-By: Claude Opus 4.6 (1M context) noreply@anthropic.com
🤖 Generated with Claude Code