Skip to content

Test run case error: Flux data #58

Open

Description

@Krishnaveni499

Hi
I'm having an issue while running the test case scenario. The test case I selected is ows papa. The problem is that even if I multiply the heat flux data with a large multiplier I am not getting any change in the output temperature. I am not able to identify the mistake. The only change I have made in the configuration file is the heat flux data file.
What might be the cause of the error and what should I do to correct the run?

Activity

  1. bolding commented on Feb 13, 2025

    @bolding
    Collaborator

    look under

    surface:
    fluxes:
    method: fairall # method to calculate fluxes from meteorological conditions [off=use prescribed fluxes, kondo=Kondo (1975), fairall=Fairall et al. (1996); default=off]

  2. Krishnaveni499 commented on Feb 13, 2025

    @Krishnaveni499
    Author

    surface:
    fluxes: # heat and momentum fluxes
    method: off # method to calculate fluxes from meteorological conditions [off=use prescribed fluxes, kondo=Kondo (1975), fairall=Fairall et al. (1996); default=off]
    heat: # prescribed total heat flux (sensible, latent and net back-radiation) [W/m^2]
    method: file # method [constant, file=from file; default=constant]
    constant_value: 0.0 # value to use throughout the simulation [W/m^2; default=0.0]
    file: heatflux_file.dat # path to file with time series [default=]
    column: 1 # index of column to read from [default=1]
    tx: # prescribed momentum flux in West-East direction [Pa]
    method: file # method [constant, file=from file; default=constant]
    constant_value: 0.0 # value to use throughout the simulation [Pa; default=0.0]
    file: momentumflux_file.dat # path to file with time series [default=]
    column: 1 # index of column to read from [default=1]
    ty: # prescribed momentum flux in South-North direction [Pa]
    method: file # method [constant, file=from file; default=constant]
    constant_value: 0.0 # value to use throughout the simulation [Pa; default=0.0]
    file: momentumflux_file.dat # path to file with time series [default=]
    column: 2 # index of column to read from [default=1]

    This is the configuration that I have done

  3. bolding commented on Feb 13, 2025

    @bolding
    Collaborator

    and how does you heat flux file look?

  4. Krishnaveni499 commented on Feb 13, 2025

    @Krishnaveni499
    Author

    1959/09/14 00:00:00 -1.544771e+02
    1959/09/14 03:00:00 -1.492934e+02
    1959/09/14 06:00:00 -1.818033e+02
    1959/09/14 09:00:00 -8.975443e+01
    1959/09/14 12:00:00 -1.115359e+02
    1959/09/14 15:00:00 -7.680168e+01
    1959/09/14 18:00:00 -6.876736e+01
    1959/09/14 21:00:00 -5.988798e+01
    1959/09/15 00:00:00 -4.307178e+01
    1959/09/15 03:00:00 -3.356252e+01
    1959/09/15 06:00:00 -8.546186e+01

    It is a dat file

  5. Krishnaveni499 commented on Feb 14, 2025

    @Krishnaveni499
    Author

    Hi sir,
    The surface heat flux from the output file does changes for both cases ie., with normal flux as above and the one with the flux multiplied with 1000. But the range of the input and output flux data has a huge difference (in the range of about 10 to the power 3).
    Even if the flux data has a change, the output temperature has no change.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment