Skip to content

hardcoded fuel moisture of extinction value on Rothermel model #35

Description

@agumartina

The fuel moisture of extinction (me from the tables) value for Rothermel model has a hardcode value and the value from the fuel table is ignored.
https://github.com/forefireAPI/firefront/blob/edbcdf90bbb610b69ed56a4b2bc9ebf9beb06f82/src/Rothermel.cpp#L173

Is this intentional? Scott & Burgan models between 15% and 40%. So some fuels stop burning earlier/later than others.

Activity

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment