Skip to content

The gateway relays the tunnel socket to the lease's worker #1113

Closed

Description

@leonardoxr

Part of #1110.

Scope

A holder opens GET /v1/leases/{id}/tunnel on a gateway, and the gateway relays it to the lease's worker over one two-way relay, as it relays the input socket. This adds both sides of that relay: the worker's relay door into #1112's tunnel sessions (channel framing, a heartbeat every 5 s, close frames) and the gateway's bridge, refusals and drain. The route's published statuses and the remote-agents page describe tunnels through a gateway.

In short

After this PR, the same tunnel socket works through a gateway: the gateway resolves the lease, opens a two-way relay to the worker's tunnel module with the worker's own lease id as the relay's lease argument, and carries frames both ways, up to 65541 bytes each. An idle tunnel stays open, because the worker's heartbeat keeps the relay alive. A worker with tunnels off answers 503 TUNNEL_UNAVAILABLE with Tunnels are off on worker <workerId>; turn on capabilities.tunnel.enabled there before the upgrade. A caller frame over 65541 bytes gets REFUSED BAD_REQUEST and close 4003, as on a lone worker. A worker that stops answering or stops closes the caller's socket 1011; the lease ending closes it 4001; the gateway stopping closes it 1001.

flowchart LR
  C[holder's socket] --> G[gateway tunnel route - new]
  G -->|relayTwoWay, lease argument = workerLeaseId - new| W[worker relay door - new]
  W --> S[#1112 tunnel sessions]
Loading
Gateway case Today After
tunnel socket, worker has tunnels on 404 upgraded and relayed
worker has tunnels off 404 503 TUNNEL_UNAVAILABLE
no answer from the worker in 10 s — 503 WORKER_UNREACHABLE
tunnel idle for a minute — stays open
worker stops answering, or is stopping — close 1011
lease ends — close 4001 with the reason (lease ended if the worker's close does not come within 2 s)
gateway stops — close 1001

If this goes wrong, a user sees a quiet tunnel through a gateway drop after 15 s, or stay open after the worker is gone.

Technical spec

Facts

Commit 31ff66e.

# Fact Source
F1 The input gateway side opens relayTwoWay(workerId, path, …, lease.workerLeaseId); the worker target reads only the lease argument src/input/gateway-link.ts:125-133, src/input/worker-link.ts:58-59, src/modules/host.ts:244-250
F2 The input relay channel frames [len u32][tag u8][payload], heartbeat 0xF0 every 5 s, close 0xF1 {code, reason} src/input/framing.ts:7-31, src/input/channel.ts:5-32
F3 The input bridge reports a worker's 1001 as 1011 Worker <id> stopped answering src/input/gateway-link.ts:93-94, src/input/AGENTS.md:44
F4 The gateway ends a two-way relay after 15 s with no byte from the worker src/gateway/relay.ts:46, src/gateway/relay.ts:427
F5 Refusals before the upgrade: RELAY_TARGET_MISSING → 503 with the module's code; no head in 10 s → 503 WORKER_UNREACHABLE src/input/AGENTS.md:47-49
F6 On leases.onRemoved the input bridge waits 2 s for the worker's 0xF1, then closes 4001 src/input/AGENTS.md:45
F7 The input gateway side closes its bridges at beforeDrain with 1001 src/input/gateway.ts:14, src/input/gateway-link.ts:110-113
F8 The input bridge drops client frames over its bound silently src/input/gateway-link.ts:78-79
F9 A route's statuses in its definition feed the OpenAPI document; the input route's 503 is pinned by a test src/input/definition.ts:29-33, src/http/openapi.test.ts:402-412
F10 The input end-to-end test drives a gateway and a worker with real relays (fleet({gatewayInput, workerInput})) src/daemon/input-lease.e2e.test.ts:377-381
F11 The uplink opens at most 64 channels per side; a tunnel run holds one src/link/index.ts:32

Modules touched

Searches: relayTwoWay( and beforeDrain in src/input, statuses in src/input/definition.ts.

  • src/tunnel/ — worker-link.ts and channel.ts (worker relay door), gateway.ts, gateway-link.ts (bridge), refusal.ts, definition.ts (503 statuses, description); tests.
  • src/daemon/ — tunnel-lease.e2e.test.ts (new) through a gateway.
  • src/http/ — openapi.test.ts pins the 503.
  • website/ — remote-agents page: tunnels through a gateway, the capability on both sides.
sequenceDiagram
  participant C as Holder
  participant G as Gateway tunnel
  participant W as Worker tunnel
  C->>G: upgrade /v1/leases/w1.3f9c/tunnel
  G->>W: relayTwoWay, lease 3f9c
  alt worker off
    W-->>G: RELAY_TARGET_MISSING
    G-->>C: 503 TUNNEL_UNAVAILABLE
  else
    G-->>C: 101, then frames both ways
    W-->>G: 0xF0 every 5 s
    W-->>G: 0xF1 {4001, expired}
    G-->>C: close 4001 expired
  end
Loading

Contract and event changes

none: TUNNEL_UNAVAILABLE is added by #1112; searched src/contract for this task's names: no other change.

Other code on the same state

Searches: relayTwoWay (input, stream), onRemoved (input gateway link), beforeDrain (input, stream gateways).

  • Input and stream sockets on the same lease: separate relays, one uplink channel each, from the shared 64 (F11).
  • Lease removal and drain: as input (F6, F7).

Failure modes

Call Outcome What happens Limit, counted from
relayTwoWay open RELAY_TARGET_MISSING 503 TUNNEL_UNAVAILABLE —
relayTwoWay open no head 503 WORKER_UNREACHABLE 10 s, from the open
relay no byte from the worker close 1011 15 s, from the last byte (F4)
relay 0xF1 {1001, …} close 1011 Worker <id> stopped answering (F3) —
relay 0xF1 {code, reason}, other codes close with that code and reason —
caller frame over 65541 bytes REFUSED BAD_REQUEST, close 4003 —
lease removed no 0xF1 close 4001 lease ended 2 s, from the removal
gateway drain — close 1001 Simlock is stopping —

No state is written.

Rules in play

Tests

Seams: the daemon end-to-end with a real gateway relay and a fake worker device, modelled on src/daemon/input-lease.e2e.test.ts (fleet, real clock, no timer cases); the gateway side with a fake relay and a fake clock, modelled on src/input/gateway.test.ts:75-140; the worker relay door with a fake clock, modelled on src/input/worker.test.ts. The 15 s silence bound itself is proven in src/gateway/relay.test.ts; this task proves the heartbeat that keeps an idle tunnel under it.

  • A holder opens the tunnel socket through a gateway and it is relayed to the lease's worker; cases: relayed HELLO/READY and a full 65541-byte DATA; REFUSED → 4003; a caller frame over 65541 bytes → 4003; worker capability off → 503 TUNNEL_UNAVAILABLE; worker stops → 1011; lease ends → 4001 with the worker's reason; gateway drains → 1001.
  • The gateway's tunnel bridge bounds every wait on the worker; cases: no head in 10 s → 503 WORKER_UNREACHABLE; the relay ends for silence → 1011; lease removed and no worker close within 2 s → 4001 lease ended.
  • The worker's relay door keeps an idle tunnel's relay alive; cases: an idle socket sends a heartbeat every 5 s; a close sends 0xF1 {code, reason}.

Done when

  • The Tests lines pass; openapi.test.ts shows the route's 503 TUNNEL_UNAVAILABLE and WORKER_UNREACHABLE.
  • The remote-agents page describes tunnels through a gateway, with the capability on both sides.

Out of scope

Depends on

Written by an agent.

Activity

  1. added
    task:ready
    on Nov 1, 2026
  2. self-assigned this
    on Nov 1, 2026
  3. added a commit that references this issue on Nov 1, 2026
    a345362
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

Labels

task:ready

Type

No type

Projects

No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions