Skip to content

Value buttons for discrete numeric values: Range step, and numeric Values lists - #7

Merged
arithex merged 3 commits into
mainfrom
claude/range-step-buttons
Oct 30, 2026
Merged

arithex merged 3 commits into
mainfrom
claude/range-step-buttons

Conversation

@arithex

@arithex arithex commented Oct 30, 2026 •

Copy link
Copy Markdown
Owner

This follows UX feedback. When a param allows only a small set of numbers, the user now picks one from a grid of buttons instead of typing it. Values already in the files that break a param's constraints are now flagged with a warning.

Description syntax

  • Range: [20-120, by 20] allows only 20, 40, 60, 80, 100 and 120. It works for integer and float params, e.g. Range: [0.5-2.0, by 0.25]. A step needs a minimum. A step with no maximum, e.g. [0-, by 5], is still enforced when values are typed, but shows no buttons.
  • Values: [8,9,10,12,16]: when every entry is a number, these are the allowed values themselves, for integer and float params. When the entries are text, e.g. Values: [Low,Medium,High], they still label the values 0, 1 and 2 in the dropdown, as before.

UI

  • When there are 21 or fewer allowed values (ParamConstraints.MaxChoices), the detail pane shows a wrapping row of buttons in place of the text box, as in the mockup. The selected button gets the accent fill. Clicking a button stages the value, and Apply & Save writes it. Fill with default selects the default's button.
  • Button labels are the values as they'll be written: integers as plain numbers, floats with at least one decimal place (1.0, 0.75). A current value that doesn't match any button, e.g. one edited by hand, leaves no button selected.
  • With more than 21 values, the text box is shown, and typed values are checked against the step or the list.
  • The line under the param name lists numeric values (Values: 8, 9, 10, 12, 16) and shows the step in the range (Range: [20 to 120, by 20]).

Warnings for existing values (CLAUDE.md: "highlight that condition")

Values already in the files are never changed. They're flagged when they're:

  • out of range,
  • not on the step grid,
  • not in a numeric Values list,
  • outside an enum's labels, or
  • a feature-flag string that doesn't match its pattern.

How they're shown:

  • List: a warning triangle next to the current value, with a tooltip that says what's wrong.
  • Detail pane: a warning line for each value that breaks the rules: Default, User.cfg and VR.cfg. For example: "User.cfg value 50 is not allowed. Value must be a multiple of 20 from 20. Range: [20 to 120, by 20]".
  • The icon is a vector shape rather than the ⚠ text character, so it doesn't depend on fonts that may be missing under Wine.

Testing

  • 56 unit tests pass: the 51 existing ones plus 5 new.
    • Step grids for integers and floats, including that 0.1 steps survive floating-point rounding.
    • A typed value that's off the grid or out of range is rejected.
    • The 21-value threshold is enforced, and an unbounded step shows no buttons.
    • Numeric Values lists for integers (font sizes) and floats (the mockup's 0.5, 0.75, 1.0, 1.5, 2.0).
    • Existing-value warnings for steps, lists, enum labels and feature flags.
  • The C# compiles against the .NET 4.8 reference assemblies, using stand-ins for the code the XAML generates.
  • Windows CI build.
  • Manual check of the button grid against the mockup, and of the warnings, in both themes.

🤖 Generated with Claude Code

https://claude.ai/code/session_01KaEsnLMDyw72GZ8a6ZxAGq

…lues lists

Per UX feedback:
- "Range: [20-120, by 20]" allows only 20,40,...,120 (int or float).
- An all-numeric "Values: [8,9,10,12,16]" lists the allowed values
  themselves (text labels still map to 0,1,2... in a dropdown).
- When there are 21 or fewer allowed values, the detail pane shows a
  wrapping grid of buttons instead of the text box; the selected one is
  highlighted, and Apply & Save writes it. Typed values (when there are
  more than 21) are validated against the step / list.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01KaEsnLMDyw72GZ8a6ZxAGq
Per CLAUDE.md: values already in the cfg files that are out of range, off
the step grid, not in a Values list, or invalid feature-flag strings are
kept as they are, but highlighted: a warning icon (with tooltip) next to
the value in the list, and a warning line per offending value (Default,
User.cfg, VR.cfg) in the detail pane.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01KaEsnLMDyw72GZ8a6ZxAGq
Path has no FillRule property (it belongs to the geometry), so the style
setter failed the XAML compile (MC4005). Use the "F0" (even-odd) prefix in
the path data instead.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01KaEsnLMDyw72GZ8a6ZxAGq
@arithex
arithex merged commit 5ae70fb into main Oct 30, 2026
2 checks passed
@arithex
arithex deleted the claude/range-step-buttons branch October 30, 2026 02:04
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment