Follow-up to the cluster-services-831 postmortem (a1ubr720p02's root disk went read-only and kubelet died). This enables the kubelet monitor and an automatic remediation that is safe to leave on: at most one rke2-agent restart per incident, only when the disk write probe (#59) passed recently, and never on a node where rke2-agent is not the enabled unit. IPMI power-cycle and node reboot are not configured anywhere.

Why the existing remediation path could not be used as-is

  1. Inverted trigger. evaluateRemediation remediates every condition whose status is False. The kubelet monitor reports its healthy state as KubeletDown=False and KubeletUnhealthy=False on every passing check, so enabling remediation would have restarted on every healthy node. TestRemediationPolicy_LegacyRuleWouldRestartHealthyKubelet pins this.
  2. Silent no-op restart. In the DaemonSet, the image's systemctl cannot reach the host systemd. It prints Running in chroot, ignoring command and exits 0, so the restart did nothing and was recorded as a success. I verified this live on a1-ops-prd.
  3. Dead alert. NodeDoctorKubeletUnhealthy matched condition_type="KubeletHealthy" == 0, which the monitor never emits.

Changes

  • Dispatch policy on a monitor's remediation block. All new fields are opt-in; when triggerConditions is unset the legacy rule is unchanged.
    • triggerConditions: problem-polarity trigger. Only the named conditions count, and only when they are True.
    • maxAttemptsPerIncident: the attempt is recorded before dispatch, so a failed or hung restart still counts and is not retried. The count resets when the condition clears.
    • cooldown: minimum time between dispatches, across incidents.
    • preconditions: checked against the latest observed condition, with an optional monitor scope and a required maxAge. A withheld dispatch does not use up the attempt.
  • systemd-restart changes.
    • requireServiceEnabled refuses unless systemctl is-enabled reports enabled. On RKE2 server nodes rke2-agent is installed but disabled, and restarting it would start a second kubelet.
    • When PID 1 is systemd and our mount namespace differs from PID 1's (hostPID container), systemctl runs through nsenter --target 1 --mount --uts --ipc --net --pid.
    • The chroot notice is always treated as an error.
  • Chart.
    • New opt-in monitors.kubelet. It checks healthz only: kubelet is not a systemd unit on RKE2, and PLEG needs authenticated access to the metrics port.
    • New monitors.kubelet.remediation with defaults rke2-agent, 1 restart per incident, 30m cooldown, write probe passed within 3m, and requireServiceEnabled.
    • The render fails if the write-probe gate is on but the write probe is disabled.
  • NodeDoctorKubeletUnhealthy now matches KubeletUnhealthy == 1.

Tests

  • Detector policy unit tests:

    • healthy kubelet → no dispatch;
    • 1 dispatch per incident;
    • a failed restart is not retried;
    • read-only, stale, missing or wrong-monitor write probe → withheld, and the attempt is kept;
    • cooldown applies across incidents;
    • recovery resets the incident.

    I mutation-checked them: disabling each guard or inverting the trigger fails at least one test.

  • systemd-restart tests: the is-enabled guard (enabled, disabled, masked, static, not-found, and dry-run), chroot detection, and the nsenter decision against a fake /proc.

  • Config validation tests.

  • End-to-end (test/integration/remediation/kubelet_restart_policy_test.go). The chain is helm template with the kubelet remediation on → util.LoadConfig → ProblemDetector → RemediatorRegistry → SystemdRemediator → a recording fake systemctl. Results:

    • agent node: exactly is-enabled rke2-agent, then restart rke2-agent, once;
    • read-only disk: no systemctl calls;
    • server node: is-enabled only, refused.

    Two chart checks: the default render has no kubelet monitor, and the render fails when the write probe is off.

Live read-only checks on a1-ops-prd (no restarts):

  • 127.0.0.1:10248/healthz answers 200 ok from all 13 node-doctor pods.
  • nsenter ... systemctl is-enabled reaches the host systemd: rke2-agent is enabled on the 10 workers and disabled on a1ubmgmtp01-03.

Refs: cluster-services-831

Enables a safe automatic kubelet remediation (cluster-services-831): restart
the unit that owns kubelet at most once per incident, only when the disk
write probe passed recently, never on a node where that unit is not enabled.

Three existing defects made the systemd-restart path unsafe or inert:
- The detector remediated every condition with status False. The kubelet
  monitor reports its HEALTHY state as KubeletDown=False and
  KubeletUnhealthy=False, so enabling remediation on it would restart on
  every passing check.
- In the DaemonSet, the image's systemctl cannot reach the host systemd. It
  prints "Running in chroot, ignoring command" and exits 0, so a restart did
  nothing and was reported as a success.
- NodeDoctorKubeletUnhealthy matched KubeletHealthy == 0, which the monitor
  never emits, so the alert could not fire.

Changes:
- Monitor remediation policy fields: triggerConditions (problem-polarity
  trigger), maxAttemptsPerIncident (attempt recorded before dispatch, so a
  failed or hung restart still counts; reset when the condition clears),
  cooldown (spans incidents), preconditions (latest observed condition,
  optional monitor scope, required maxAge; a withheld dispatch does not use
  up the attempt). Without triggerConditions the legacy rule is unchanged.
- systemd-restart: requireServiceEnabled refuses unless systemctl is-enabled
  says "enabled" (rke2-agent is disabled on RKE2 server nodes). systemctl
  runs via nsenter into PID 1's namespaces when PID 1 is systemd and our mount
  namespace differs, and the chroot notice is always an error.
- Chart: opt-in monitors.kubelet (healthz only; no systemd/PLEG check on
  RKE2) with monitors.kubelet.remediation (rke2-agent, 1 per incident, 30m
  cooldown, write probe within 3m, requireServiceEnabled). The render fails
  if the write-probe gate is on but the write probe is off. Node reboot or
  power-cycle is not configurable from this block.
- Fix the NodeDoctorKubeletUnhealthy rule to KubeletUnhealthy == 1.

Tests: detector policy unit tests (mutation-checked); systemd is-enabled
guard, chroot detection and nsenter decision tests; config validation tests;
an end-to-end test from helm template through LoadConfig, the detector, the
registry and SystemdRemediator to a recording systemctl, covering one restart
per incident, no restart on a read-only disk, and refusal on a server node.

Refs: cluster-services-831
Comment thread pkg/remediators/systemd.go Fixed
@mattmattox
mattmattox merged commit e53f2ed into main Oct 15, 2026
11 checks passed
@mattmattox
mattmattox deleted the feat/kubelet-remediation-policy branch October 15, 2026 16:03
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment