Skip to content

Change to Sensor from PollingSensor for SQS Sensor #90

Open

Description

@grepory

Right now, the PollingSensor caps at 10 messages per second due to the API limit for maximum messages in a transaction and the minimum polling rate of 1 Hz.

We have modified the SQS sensor locally to be a continuously running Sensor that does its own polling loop instead of a scheduled poll as we have to handle 30+ messages per second. Would this be a welcomed upstream contribution?

Activity

  1. Kami commented on Dec 18, 2019

    @Kami
    Contributor

    Yeah, the contribution would be more than welcome.

    For backward compatibility and similar reasons, it would probably be good to add it as a separate sensor though.

  2. grepory commented on Dec 18, 2019

    @grepory
    Author

    That makes sense to me. Thanks!