The SNZB-02M sub-driver was added but never registered, so the pressure display feature was dead code on the device. Register it via sub_drivers.lua, drop the unrelated SNZB-02LD/WD handler and utils (not in this driver, and referencing a nonexistent sub-driver), and add unit tests for pressure conversion and refresh. Co-Authored-By: Claude <noreply@anthropic.com>
ae161d5 to
b5e3665
Compare
cjswedes
left a comment
There was a problem hiding this comment.
My biggest concern is the lack of configuration for reporting the PressureMeasurement MeasuredValue attribute; has this been tested manually?
There was a problem hiding this comment.
Is there a reason to have the nested directories? We should just add a sonoff subdriver rather than having sonoff/SNZB-02M. We want to avoid having single subdrivers for each model.
There was a problem hiding this comment.
Please change the directory structure so that it is not nested, and everything falls under the sonoff directory.
|
It looks like temperature, humidity, and battery reporting are not configured specifically for this model. So the default configs are used. The defaults are coarser than what's configured for the |
| minimum_interval = 5, | ||
| maximum_interval = 3600, | ||
| data_type = PressureMeasurement.attributes.MeasuredValue.base_type, | ||
| reportable_change = 50 |
There was a problem hiding this comment.
The PressureMeasurement.MeasuredValue attribute is in units of 0.1 kPa. So 50 means 5 kPa. Normal barometric changes are roughly 0.1–0.5 kPa per hour. So the device would almost never report on change. Can you confirm if this was tested on a real device and if this setting is desired?
| device:add_configured_attribute(PRESSURE_CONFIGURATION) | ||
| end | ||
|
|
||
| local function refresh_handler(driver, device, command) |
There was a problem hiding this comment.
This handler looks redundant. I removed it locally, and the default refresh (device:refresh()) sends the same four reads: temperature, humidity, pressure (configured via add_configured_attribute) and battery percentage. The existing refresh test still passes unchanged with relaxed ordering. Could you drop refresh_handler and its capability_handlers entry unless there’s a read the default misses?
| device:emit_event(capabilities.atmosphericPressureMeasurement.atmosphericPressure({value = pressure_value, unit = "kPa"})) | ||
| end | ||
|
|
||
| local function device_init(driver, device) |
There was a problem hiding this comment.
nit: A subdriver’s lifecycle_handlers.init replaces the parent’s device_init for this model instead of running alongside it. That’s harmless today, because configurations.lua has no SNZB-02M entry. If one is added later, its attributes will silently stop being configured. A one-line comment here would save the next person some debugging.
| local function pressure_report_handler(driver, device, value, zb_rx) | ||
| local pressure_value = convert_pressure_value(value.value) | ||
| if pressure_value == nil then | ||
| log.warn(string.format("SNZB-02M pressure report has no value: %s", tostring(value))) |
There was a problem hiding this comment.
The nil branch (log and return) has no test. Either add a small test for a report with no value, or drop the nil handling, since the framework always passes a value for this attribute.
| direction = "receive", | ||
| message = { | ||
| mock_device.id, | ||
| PressureMeasurement.attributes.MeasuredValue:build_test_attr_report(mock_device, 960) |
There was a problem hiding this comment.
The only pressure test uses 960. Could you add a second case with a non-round value, such as 1013, so the division by 10 is covered more than once?
| } | ||
| ) | ||
|
|
||
| test.run_registered_tests() |
There was a problem hiding this comment.
I don’t see a test that covers the pressure reporting configuration, which was @cjswedes's main concern earlier in the review. Please add one that checks device_init adds the pressure configuration and that doConfigure sends the bind and configure-reporting messages for cluster 0x0403.
There was a problem hiding this comment.
Lets remove sonoff from this profile name (and file name), so that other devices can use it if there are any others.